ZHAO Lijie, SONG Guofang, XING Jiansheng, HUANG Peng, JI Luyu, WANG Fei, AN Shizhong, ZHU Pengfei, LIU Jie. The Beam Screening Device for the Production of Radioisotopes Based on 100 MeV High-Flow Proton Cyclotron[J]. Journal of Isotopes, 2024, 37(3): 288-293. DOI: 10.7538/tws.2023.youxian.108
Citation: ZHAO Lijie, SONG Guofang, XING Jiansheng, HUANG Peng, JI Luyu, WANG Fei, AN Shizhong, ZHU Pengfei, LIU Jie. The Beam Screening Device for the Production of Radioisotopes Based on 100 MeV High-Flow Proton Cyclotron[J]. Journal of Isotopes, 2024, 37(3): 288-293. DOI: 10.7538/tws.2023.youxian.108

The Beam Screening Device for the Production of Radioisotopes Based on 100 MeV High-Flow Proton Cyclotron

  • In some radioisotope production experiments, 100 MeV high-current proton cyclotron is required to extract a single-turn beam to meet the experimental requirements, but at present, there is a serious problem of turn overlap when the beam is extracted, and a beam screening device needs to be designed to improve the quality of the drawn beam. The beam screening device has a frame structure and slit motion system based on the cyclotron, and a control system based on PLC design to control the stepper motor and use the electronic ruler and PID control algorithm to achieve closed-loop control. After many times of operation and debugging, the motion accuracy of the mechanical device is ±0.2 mm, and the beam screening can be realized during the operation of the accelerator, which has reference significance for the design and manufacture of the cyclotron beam screening device.