Energy Spectrum to Dose Conversion Method Used in Environmental Radiation Dose Measurement

  • In order to accurately measure the environmental level dose rate, based on the G(E) function method and conversion of complete spectra without deconvolution method, the energy spectrum and dose rate of X/γ ray was measured for calculating spectrum-dose conversion coefficient. And finally the conversion of energy spectrum to dose rate is realized. The residual difference between the calculated dose rate by the energy spectrum-dose method and the measured dose rate value is approximately 0, which proves that the method is self-consistent. Experiments have been conducted in 137Cs and 60Co radiation fields, and the maximum relative error of dose rate is ±10%, which proves that the G(E) function method and Conversion of complete spectra without deconvolution method are feasible for energy spectrum-dose conversion.