TIAN Li-li, ZHANG Feng, WANG Xin-guang, LIU Jun-tao. Monte Carlo Study on Gas Pressure Response of He-3 Tube in Neutron Porosity Logging[J]. Journal of Isotopes, 2016, 29(2): 98-102. DOI: 10.7538/tws.2016.29.02.0098
Citation: TIAN Li-li, ZHANG Feng, WANG Xin-guang, LIU Jun-tao. Monte Carlo Study on Gas Pressure Response of He-3 Tube in Neutron Porosity Logging[J]. Journal of Isotopes, 2016, 29(2): 98-102. DOI: 10.7538/tws.2016.29.02.0098

Monte Carlo Study on Gas Pressure Response of He-3 Tube in Neutron Porosity Logging

  • Thermal neutrons are detected by (n,p) reaction of Helium-3 tube in the compensated neutron logging. The helium gas pressure in the counting area influences neutron detection efficiency greatly, and then it is an important parameter for neutron porosity measurement accuracy. The variation law of counting rates of a near detector and a far one with helium gas pressure under different formation condition was simulated by Monte Carlo method. The results showed that with the increasing of helium pressure the counting rate of these detectors increased firstly and then leveled off. In addition, the neutron counting rate ratio and porosity sensitivity increased slightly, the porosity measurement error decreased exponentially, which improved the measurement accuracy. These research results can provide technical support for selecting the type of Helium-3 detector in developing neutron porosity logging.
  • loading

Catalog

    Turn off MathJax
    Article Contents

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return