LIN Hui, XIAO Xue-fu, HOU Yue-xin, ZHAO Jing, JIAN Li-min. Application Research of Quasi-monochromatic X-ray Machine Replacing 241Am Radioactive Source in Thickness Measurement[J]. Journal of Isotopes, 2014, 27(2): 122-125. DOI: 10.7538/tws.2014.27.02.0122
Citation: LIN Hui, XIAO Xue-fu, HOU Yue-xin, ZHAO Jing, JIAN Li-min. Application Research of Quasi-monochromatic X-ray Machine Replacing 241Am Radioactive Source in Thickness Measurement[J]. Journal of Isotopes, 2014, 27(2): 122-125. DOI: 10.7538/tws.2014.27.02.0122

Application Research of Quasi-monochromatic X-ray Machine Replacing 241Am Radioactive Source in Thickness Measurement

  • In the research of BS-03 thickness detector, a self-designed quasi-monochromatic (50-60 keV) X-ray machine was studied as a substitution to Am-241 low energy photon source(1.11×109 Bq)The range of output current, the attenuation of X rays through the steel plate, the aluminum plate, and the organic glass plate and stability of quasi-monochromatic X-ray machine was tested. The result showed that quasi-monochromatic X-ray machine could be an applicable replacement of Am-241 radioactive source.
  • loading

Catalog

    Turn off MathJax
    Article Contents

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return