有源中子计数法测量铀总量方法研究

Research on Uranium Mass Determination Methodology Using Active Neutron Counting

  • 摘要: 含铀物料中铀总量是核材料衡算与控制中最关注的信息之一,因非破坏性测量分析方法(NDA)不破坏样品,不产生二次废物,可对样品整体测量,因此常用作含铀物料中铀总量的测量分析。本研究基于有源中子计数法建立测量含铀物料中铀总量的新方法。对10组铀的标准样品进行测量分析,结果表明,测量误差为1.7%,小于5%,达到非破坏性分析技术的误差水平,该方法利用了不同丰度的样品确定有效235U质量计算公式,用于确定铀总量。该方法适用性广,可以用于铀物料的快速核实无损测量。

     

    Abstract: Uranium material is a very important ingredient of nuclear industry, it is also a very important object in the field of nuclear safeguards. How to accurately determine the mass of uranium in nuclear material is a popular research topic of non-destructive assay. Nowadays, active non-destructive assay is the most usual assay to accurately determine the mass of uranium in nuclear material. Previous active neutron detection assay is the quality of calibration, but this report use a new method of active neutron detection, this report include principle of measurement, method of measurement, the experimental process, data processing and result analyzing. This research explores and validates new method with measuring and analyzing 10 group of uranium samples. From the measurements result, the measurement error is 1.7%, which is within non-destructive error(5%), improve that this method is available. In the process of method establishment, using different abundance uranium samples to confirm the formula to calculate effective mass of 235U, applicable to the same conditions to rapid non-destructive measurements.

     

/