  • 摘要: 用于63Ni辐生伏特电池的片状63Ni源β粒子发射率存在难于测量的问题,本文根据闪烁探测器的测量原理建立了闪烁电流法的相对测量方法。利用该测量方法对自制的63Ni源的发射率进行了测量,对所测结果进行了分析,初步认为闪烁电流法是一种用于测量高发射率片状63Ni源β粒子发射率的可行方法。

     

    Abstract: For the problem of measurement difficulties of β particle emission rate of Ni-63 source plate used for Ni-63 betavoltaic battery, a relative test method of scintillation current method was erected according to the measurement principle of scintillation detector.β particle emission rate of homemade Ni-63 source plate was tested by the method, and the test results were analysed and evaluated, it was initially thought that scintillation current method was a feasible way of testing β particle emission rate of Ni-63 source plate with high β particle emission rate.

     

/