血清降钙素放射免疫分析

  • 摘要: 采用氯胺T法对人降钙素(hCT,以下简称CT)进行125I标记,用SephadexG-50柱分离纯化,得到比活度>9.5TBq/g、放化纯度>95%、与过量抗体结合率为(85—91)%的125I-CT。建立了稳定的冻干系列标准及简便、快速的分析方法。标准曲线范围为8.8—351pmol/L,在该范围内测定人血清的平均回收率为(95.5—102.0)%,高浓度血清的稀释相关系数为r=0.9993—0.9998,灵敏度为5.3pmol/L,批内变异系数为(3.2—8.6)%,批间变异系数为(4.7—10.4)%,非特异结合率为(2.4—4.7)%,健康人血清CT含量的正常值为11.7±6.4pmol/L。

     

    Abstract: RADIOIMMUNOASSAY FOR THYROCALCITONIN IN SERUMSu Jingxian\ Han Shiquan\ Hou Yue\ Liu Yibing\ Chen Jian\ Hou Huiren(Department of Isotope, China Institute of Atomic Energy, Beijing 102413)ABSTRACTA specific radioimmunoassay(RIA) for thyrocalcitonin(CT) is developed and applied to the measurment of serum. CT is iodinated according to the method of chT and purified by Sephadex G50. The specific activity of 125ICTB more than 9.5 TBq/g,the radiochemical purity is more than 95% and the excessive antibody binding is (85-91)%. The kit has a stable lyophilization standards. The range of detection is 8.8-351 pmol/L. This method is simple and fast. The average recovery in serum is (95.5-102.0)%.The intra and inter coefficients of variation are (3.2-8.6)% and (4.7-10.4)%,respectively. The nonspecific binding is (2.4-4.7)%,the sensitivity is 5.3 pmol/L and the correlation coefficient of high value serum dilution is 0.999 3-0.999 8.The content of CT in 82 healthy adults is 11.7±6.4 pmol/L.Key words thyrocalcitonin(CT)\ radioimmunoassay(RIA) labeling of 125I

     

/