中子水分计测量焦炭水分的误差分析

  • 摘要: 分析了钢铁工业中中子水分仪测量焦炭水分的误差.结果指出:产生误差的主要原因是由于现场定标时,所取样品的空间位置不准确.相比之下,仪表本身的误差及统计涨落都比较小.因此现场定标时应尽量增大取样比,在适中体积的料仓上可以获得较好的定标结果.

     

    Abstract: THE ERROR ANALYSIS OF COKE MOISTURE MEASURED BY NEUTRON MOISTURE GAUGETian Huixing(Shougang Electronic Instrument Compang,Beijing 100041) The error of Coke moisture measured bv neutron method in the iron and steel industry is ana-lyzed.The main cause of errors is inaccurate sampling location in the calibration procedure on site. Bycomparison, the instrument error and the statistical fluctuation error are smaller.So the sampling pro-portion should be increased as large as possible in the calibration procedure on site,and a satisfied cali-bration effect can be obtained on a suitable size hopper.Key words neutron moisture gauge coke calibration error analysis

     

/