sTSH、FT_3、FT_4甲状腺功能检测中的应用对甲状腺疾病及非甲状腺疾病的诊断

  • 摘要: 报告用国产磁分离法药盒的-TSH(IRMA)、M-FT_(3)、M-FT_(4)(RIA)测定正常人TSH62例,FT_3及FT_4各109例,其均值分别为2.57±1.16mIU/1、3.761±1.53pmol/l及17.10±4.41pmol/1。测定甲亢61例、甲减55例,其TSH、FT_3及FT_4均值分别为0.25±0.09mIU/1、16.41±5.08pmol/1、49.57+14.93pmol/l及17.24±l3.82mIU/1、1.12+0.48pmol/1、5.04±2.45pmol/1。还分别测定了44例低T_3综合症TT_3、TT-4及TSH、FT_3、FT_4在血循中的水平,并加以讨论。认为TSH、FT_3、FT_4检测对提高甲状腺疾病临床诊断的准确率有重要价值。

     

    Abstract: CLINICAL APPLICATION OF sTSH IRMA AND FT_3,FT_4 RIA FOR THYROID FUNCTION DIAGNOSES ON THE THYROID DISEASES AND NONTHYROID ILLNESSES Chen Rendu Ji Huizhi Han Xiuqing Guo Suping Zhang Wei(Nuclear Medicine Deoartment of the First Teaching Hospital in shanxi Medical Couege,Taiyuan 030001)ABSTRACT sTSH(IRMA)and FT_3,FT_4(RIA)kits which were made in China Institute of Atomic Energy areused tO measure serum TSH,FT_3 ,FT_4 concentrations in171 normal subjects.The mean values are2.57±1.16 mIU/1,3.76±1.53 pmol/l and l 7.1±4.4 l pmol/l respectively.61 hyperthyroid and55 hypothyroid patients are measured ,too. Their mean values of TSH,FT_3 and FT_4 are 0.25±0.09mIU/1,16.41±5.08 pmol/1.49. 57±14.93 pmol/1;17.24 ± l3.82 mIU/1,1.12l± 0.48pmol/1,5.04土2. 45 pmol/l respectively. Furthermore,sTSH,FT_3 and FT_4 are detected and dis-cussed in the 44 nonthyroid ilInesses(NTI).All of TT_3 mean values for NTI are less than those of nor-mal subjects,so this kind of diseases is named low T_3 syndrome.The study deems that sTSH,FT_3 andFT_4 tests are very important and valuable in the diagnosis and differential diagnosis Of thyroid diseasesand NTI.Key Words M-TSH M-FT_3 M-FT_4 low T_3 syndrome

     

/

返回文章
返回