手提式X光机~(125)I点源的研制
AN ~(125)I POINT SOURCE FOR PORTABLE X-RAY RADIOGRAPH
-
摘要: <正> 一、引言 早在六十年代初,国外有人用电化学方法研制过~(125)I点源,也有人用AgI沉淀法制成~(125)I对照源,并与升华法由活性炭吸附制成的~(125)I源作对比分析。七十年代初,Abstract: A method of preparation of portable X-ray radiographic ~(125)I point source is reported. ~(125)I was extracted into CC1_4 solvent with an oxidizing agent in an acidic medium. The organic phase was separated from aqueous solution by centrifugation. Then a radioactive point source was prepared by adsorption of ~(125)I on activated charcoal particles from the organic solvent under shaking condition. The total recovery efficiency of ~(125)I is more than 90%.The source activity may be as much as 400GBq.